Experimental investigation on split type window Air conditioner using HFC and HC mixture as ecofriendly refrigerant alternate to HCFC-22

Karthik, Ganapathi and Parthiban, A. and Sasikumar, C. and Krishnan, B. Radha and Vijayan, V. and Senthil Kumar, T.S. (2023) Experimental investigation on split type window Air conditioner using HFC and HC mixture as ecofriendly refrigerant alternate to HCFC-22. E3S Web of Conferences, 399. 06004. ISSN 2267-1242

[thumbnail of Experimental_investigation_on_split_type_window_Ai.pdf] Archive
Experimental_investigation_on_split_type_window_Ai.pdf

Download (973kB)

Abstract

t. This paper reports on an experimental study evaluating a window air conditioner's performance when R152a/R290/R600/R600a refrigerant mixture (by various mass percentages) is used as a possible alternative to R-22. Alternative refrigerants are local, cheap, and environmentally friendly. Unmodified R-22 window AC was charged with R152a/R290/R600/R600a. During the experiment, parameters such as coefficient of performance, refrigeration effect, pressure ratio, compressor discharge temperature, refrigerant
mass flow rate, and compressor power are analyzed. The present work shows that R152a-15%/R290-
15%/R600-35%/R600a-35% is the best-performing alternative refrigerant. Proposed blends and R22's
performance were comp