Estimation of biphasic isophane insulin 30/70 by using validated RP-HPLC technique

Varuni, K. and Aanandhi, M. Vijey and Gandhimathi, R. (2023) Estimation of biphasic isophane insulin 30/70 by using validated RP-HPLC technique. Annals of Phytomedicine An International Journal, 12 (1). ISSN 22789839

[thumbnail of 72.pdf] Text
72.pdf

Download (934kB)

Abstract

A rapid, specific, reliable, and repeatable RP-HPLC method for estimating biphasic isophane insulin
developed. A pH 2.3 sodium sulphate anhydrous buffer is used as mobile phase-A and acetonitrile (76:26)
is used as mobile phase-B in the most current verified isocratic RP-HPLC analytical method. The samples
were separated using a Zorbax C18 (4.6 x 250 mm), 3.5 m column at a 1.0 ml/min flow rate. The
recommended wavelength for ultraviolet detection was discovered to be 214 nm. This technique was
evaluated for the investigation of biphasic isophane insulin and its desamido the degradation product in
the form of phenol and m-cresol, which are present in small amounts as preservatives in commercial
preparations of biphasic isophane insulin. The technique was discovered to be linear over the concentration
range of 80-120% with coefficient regression r2
= 0.9995. The mean recovery was determined to be in the
range of 99.40% during accuracy tests. A rapid, accurate, linear, low-cost, and reliable RP-HPLC technology
is designed and validated in compliance with ICH standards. Since it has been demonstrated to be reliable,
this method can now be regularly used to evaluate biphasic isophane insulin

Item Type: Article
Subjects: Pharmaceutical Chemistry and Analysis > Pharmaceutical Analysis
Domains: Pharmaceutical Chemistry and Analysis
Depositing User: Mr IR Admin
Date Deposited: 31 Aug 2025 06:58
Last Modified: 31 Aug 2025 06:58
URI: https://ir.vistas.ac.in/id/eprint/10682

Actions (login required)

View Item
View Item